Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
3VA2440-5HL32-0JA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC |
------ |
|
3VA2440-5HL32-0JC0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC 2 auxiliary switches HQ |
------ |
|
3VA2440-5HL32-0JH0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2440-5HL32-0JL0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective trip unit signaling switch |
------ |
|
3VA2440-5HL32-0KA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 220-250 V DC, 208-277 V AC |
------ |
|
3VA2440-5HL32-0KC0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 220-250 V DC, 208-277 V AC 2 auxiliary switches HQ |
------ |
|
3VA2440-5HL32-0KH0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 220-250 V DC, 208-277 V AC 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2440-5HL32-0KL0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Shunt release (STL) 220-250 V DC, 208-277 V AC 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective trip unit signaling switch |
------ |
|
3VA2440-6HL32-0AB0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 2 auxiliary switches HP |
------ |
|
3VA2440-6HL32-0AC0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 2 auxiliary switches HQ |
------ |
|
3VA2440-6HL32-0AD0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 3 auxiliary switches HQ |
------ |
|
3VA2440-6HL32-0AE0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 4 auxiliary switches HQ |
------ |
|
3VA2440-6HL32-0AF0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 1 auxiliary switch HQ 1 tripped signaling contact HQ |
------ |
|
3VA2440-6HL32-0AG0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 1 auxiliary switch HP 1 tripped signaling contact HP |
------ |
|
3VA2440-6HL32-0AH0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2440-6HL32-0AJ0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal 2 auxiliary switches HP 1 tripped signaling contact HP |
------ |
|
3VA2440-6HL32-0BA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 24V DC |
------ |
|
3VA2440-6HL32-0BC0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 24 V DC 2 auxiliary switches HQ |
------ |
|
3VA2440-6HL32-0BH0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 24 V DC 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2440-6HL32-0BL0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 24 V DC 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective trip unit signaling switch |
------ |
|
3VA2440-6HL32-0CA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 120-127V AC 50/60Hz |
------ |
|
3VA2440-6HL32-0CC0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 120-127 V AC 50/60 Hz 2 auxiliary switches HQ |
------ |
|
3VA2440-6HL32-0CH0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 120-127 V AC 50/60 Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2440-6HL32-0CL0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 120-127 V AC 50/60 Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective trip unit signaling switch |
------ |
|
3VA2440-6HL32-0DA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU320, LI, In=400 A Overload protection Ir=160 A...400 A short-circuit protection Ii=1.5...12 x In Lug terminal Undervoltage release (UVR) 208-230 V AC 50/60 Hz |
------ |
|