Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
3VA2463-7JP32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU550, LSI, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal |
------ |
|
3VA2463-7JP42-0AA0 |
5.7 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU550, LSI, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection adjustable (OFF, up to 100%) Lug terminal |
------ |
|
3VA2463-7JQ32-0AA0 |
5.156 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU560, LSIG, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal |
------ |
|
3VA2463-7JQ42-0AA0 |
5.7 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU560, LSIG, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection adjustable (OFF, up to 100%) Ground fault protection, can be switched off Ig=0.2...1 x In= tg=0.05-0.8s Lug terminal |
------ |
|
3VA2463-7KP32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU850, LSI, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal |
------ |
|
3VA2463-7KP42-0AA0 |
5.7 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU850, LSI, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection adjustable (OFF, up to 100%) Lug terminal |
------ |
|
3VA2463-7KQ32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal |
------ |
|
3VA2463-7KQ42-0AA0 |
5.7 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU860, LSIG, In=630 A Overload protection Ir=250 A...630 A short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In N-conductor protection adjustable (OFF, up to 100%) Ground fault protection, can be switched off Ig=0.2...1 x In= tg=0.05-0.8s Lug terminal |
------ |
|
3VA9257-0LF10 |
0.055 |
Adapter safety lock Accessory compartment Accessory for: 3VA1 250 |
------ |
|
3VA9987-0TG11 |
0.024 |
Mounting rail adapter for T branch Accessory for: 3VA |
------ |
|
3VA9988-0BF21 |
0.138 |
Time-delay device fixed delay 110V AC Accessory for: 3VA undervoltage release |
------ |
|
3VA9988-0BF22 |
0.134 |
Time-delay device fixed delay 230V AC Accessory for: 3VA undervoltage release |
------ |
|
3VA9988-0BF23 |
0.117 |
Time-delay device fixed delay 24V DC Accessory for: 3VA undervoltage release |
------ |
|
3VA9988-0BM10 |
0.085 |
Shunt release left for electrical interlock 24V DC Accessory for: 3VA1/2 |
------ |
|
3VL9400-3JS01 |
0.01 |
Breaker VLVAR DEPTH 1 3R 12 J/L-FR 3/4P |
------ |
|
3VL9400-3JS11 |
0.01 |
Breaker VLVAR DEPTH 1 3R 12 J/L-FR 3/4P |
------ |
|
3VL9400-3JS41 |
0.01 |
Breaker VLVAR DEPTH 4x J/L-FR 3/4P |
------ |
|
3VL9400-3JS51 |
2.353 |
Breaker VLVAR DEPTH 4x J/L-FR BLK HDL |
------ |
|
3VL9600-3JJ41 |
0.516 |
ACC Circuit Breaker Extension SH. RHVMS2 (CAT NO. RHVMS24) |
------ |
|
3VT9210-6BC00 |
0.276 |
Overcurrent release VT250, 4-pole, system protection ETU DPN, LI IR=40...100 A, Overload protection IRM=4...8k A Short-circuit protection Neutral conductor protection, IRN=0.5 to 1xIR Screw-connect connections in scope of delivery: Switchover unit |
------ |
|
3VT9216-6BC00 |
0.274 |
Overcurrent release VT250, 4-pole, system protection ETU DPN, LI IR=63...160 A, Overload protection IRM=4...8k A Short-circuit protection Neutral conductor protection, IRN=0.5 to 1xIR Screw-connect connections in scope of delivery: Switchover unit |
------ |
|
3VT9325-6BC00 |
0.304 |
Overcurrent release VT630, 4-pole, system protection ETU DPN, LI IR=100...250 A, Overload protection IRM=2...9 kA, Short-circuit protection Neutral conductor protection, IRN=0.5 to 1xIR Screw-connect connections in scope of delivery: |
------ |
|
3WL9111-0AA42-0AA0 |
0.7 |
Set consisting of 3 current transformers only Rogowski coil without iron core with warning label and manual for 3-pole 3WL FS 1 |
------ |
|
3WL9111-0AA43-0AA0 |
0.9 |
Set consisting of 3 current transformers only Rogowski coil without iron core with warning label and manual for 3-pole 3WL FS 2 |
------ |
|
3WL9111-0AA44-0AA0 |
1.6 |
Set consisting of 3 current transformers only Rogowski coil without iron core with warning label and manual for 3-pole 3WL FS 3 |
------ |
|