Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
3VA2450-6JQ32-0AA0 |
4.753 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU560, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-6JQ42-0AA0 |
4.8 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85 kA @ 415 V 4-pole, system protection ETU560, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection adjustable (OFF, up to 100%) Ground fault protection, can be switched off Ig=0.2...1 x In= tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-6KP32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU850, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal |
------ |
|
3VA2450-6KP42-0AA0 |
4.8 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85 kA @ 415 V 4-pole, system protection ETU850, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection adjustable (OFF, up to 100%) Lug terminal |
------ |
|
3VA2450-6KQ32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85kA @ 415V 3-pole, system protection ETU860, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-6KQ42-0AA0 |
4.8 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class H Icu=85 kA @ 415 V 4-pole, system protection ETU860, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection adjustable (OFF, up to 100%) Ground fault protection, can be switched off Ig=0.2...1 x In= tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-7HK32-0AA0 |
4.3 |
ВЫКЛЮЧАТЕЛЬ В ЛИТОМ КОРПУСЕ 3VA2 IEC ТИПОРАЗМЕР 630 КЛАСС ОТКЛ. СПОСОБНОСТИ C ICU=110KA @ 415 В 3-ПОЛЮС., ЗАЩИТА ЛИНИИ ETU340, ELISA LI, IN=500A ЗАЩИТА ОТ ПЕРЕГРУЗКИ IR=200A .. .500A ЗАЩИТА ОТ ТОКА КЗ II=14 X IN ШИННОЕ ПРИСОЕДИНЕНИЕ |
------ |
|
3VA2450-7HK42-0AA0 |
5.7 |
ВЫКЛЮЧАТЕЛЬ В ЛИТОМ КОРПУСЕ 3VA2 IEC ТИПОРАЗМЕР 630 КЛАСС ОТКЛ. СПОСОБНОСТИ C ICU=110KA @ 415 В 4-ПОЛЮС., ЗАЩИТА ЛИНИИ ETU340, ELISA LI, IN=500A ЗАЩИТА ОТ ПЕРЕГРУЗКИ IR=200A .. .500A ЗАЩИТА ОТ ТОКА КЗ II=14 X IN РЕГУЛИР. ЗАЩИТА НЕЙТРАЛИ (OFF,50%,100%) ШИННОЕ ПРИСОЕДИНЕНИЕ |
------ |
|
3VA2450-7JP32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU550, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal |
------ |
|
3VA2450-7JP42-0AA0 |
4.8 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU550, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection adjustable (OFF, up to 100%) Lug terminal |
------ |
|
3VA2450-7JQ32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU560, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-7JQ42-0AA0 |
4.8 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU560, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection adjustable (OFF, up to 100%) Ground fault protection, can be switched off Ig=0.2...1 x In= tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-7KP32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU850, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal |
------ |
|
3VA2450-7KP42-0AA0 |
4.8 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU850, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection adjustable (OFF, up to 100%) Lug terminal |
------ |
|
3VA2450-7KQ32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-7KQ42-0AA0 |
4.8 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 4-pole, system protection ETU860, LSIG, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N-conductor protection adjustable (OFF, up to 100%) Ground fault protection, can be switched off Ig=0.2...1 x In= tg=0.05-0.8s Lug terminal |
------ |
|
3VA2450-7MN32-0AA0 |
4.3 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal |
------ |
|
3VA2450-7MN32-0AB0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 2 auxiliary switches HP |
------ |
|
3VA2450-7MN32-0AC0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 2 auxiliary switches HQ |
------ |
|
3VA2450-7MN32-0AD0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 3 auxiliary switches HQ |
------ |
|
3VA2450-7MN32-0AE0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 4 auxiliary switches HQ |
------ |
|
3VA2450-7MN32-0AF0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 1 auxiliary switch HQ 1 tripped signaling contact HQ |
------ |
|
3VA2450-7MN32-0AG0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 1 auxiliary switch HP 1 tripped signaling contact HP |
------ |
|
3VA2450-7MN32-0AH0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2450-7MN32-0AJ0 |
4.4 |
Circuit breaker 3VA2 IEC Frame 630 Switching capacity class C Icu=110 kA @ 415 V 3-pole, motor protection ETU350M, LSI, In=500 A Overload protection Ir=200 A...500 A short-circuit protection Isd=3...15 x Ir, Ii=15 x In Lug terminal 2 auxiliary switches HP 1 tripped signaling contact HP |
------ |
|