Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
2AT0421-1AH82-2GR2 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWGD, Size: 10; Coolant: Water; Installation: Base frame, Steel; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package J; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AH82-4AF4 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWGD, Size: 10; Coolant: Water; Installation: Base frame, Steel; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package E; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN66-3SV8 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AI; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN66-5LL1 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AK; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN66-7EA3 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AN; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN66-8WP5 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AM; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN67-1QD7 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BI; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN67-3HT0 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BK; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN67-5BH2 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BN; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AN67-6TW4 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTD, Size: 10; Coolant: Water; Installation: Tank; Pump type: Double pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BM; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 2x9.00kW; |
------ |
|
2AT0421-1AP31-3FA7 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AL; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0421-1AP31-4XQ0 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AK; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0421-1AP31-6RE2 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AN; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0421-1AP31-8JT4 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package AM; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0421-1AP32-1CH6 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BL; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0421-1AP32-2UW8 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BK; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0421-1AP32-4NM1 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BN; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0421-1AP32-6GB3 |
0 |
FLENDER Oil supply system; Pressurized oil and lubricating Type: OWTE, Size: 10; Coolant: Water; Installation: Tank; Pump type: Single pump, Gear wheel; Oil filter type: Double changeover filter; Display/Monitoring: Package BM; Degree of protection: IP55; Line voltage: 460 V; Line frequency: 60 Hz; Oil flow rate: 204.0 l/min; Rated power supply: Pump motor: 1x9.00kW; |
------ |
|
2AT0430-0AA00-0AA0 |
16 |
FLENDER Oil supply system; Cooling unit with ext. pump; Type: OLOO, Size: 2; Coolant: air; Installation: Base frame, Steel; Oil flow rate: acc. to external pump: min. 15 l/min, max. 130 l/min; Max. working pressure: 16 bar; Nominal fan speed: 1200 1/min; Line voltage: 400 V; Line frequency: 50 Hz; Degree of protection: IP55; Motor efficiency class: IE2; Rated power supply: Fan motor: 0.25 kW at 50 Hz; |
------ |
|
2AT0430-0DJ30-6DQ7 |
16 |
FLENDER Oil supply system; Cooling unit with ext. pump; Type: OLOO, Size: 2; Coolant: air; Installation: Base frame, Steel; Oil flow rate: acc. to external pump: min. 15 l/min, max. 130 l/min; Max. working pressure: 16 bar; Nominal fan speed: 1200 1/min; Line voltage: 460 V; Line frequency: 60 Hz; Degree of protection: IP55; Motor efficiency class: IE2; Rated power supply: Fan motor: 0.29 kW at 60 Hz; |
------ |
|
2AT0430-0GS61-3HG5 |
16 |
FLENDER Oil supply system; Cooling unit with ext. pump; Type: OLOO, Size: 2; Coolant: air; Installation: Base frame, Steel; Oil flow rate: acc. to external pump: min. 15 l/min, max. 130 l/min; Max. working pressure: 16 bar; Nominal fan speed: 1200 1/min; Line voltage: 400 V; Line frequency: 50 Hz; Degree of protection: IP55; Motor efficiency class: IE2; Rated power supply: Fan motor: 0.18 kW at 50 Hz; |
------ |
|
2AT0430-0LC02-0LX3 |
16 |
FLENDER Oil supply system; Cooling unit with ext. pump; Type: OLOO, Size: 2; Coolant: air; Installation: Base frame, Steel; Oil flow rate: acc. to external pump: min. 15 l/min, max. 130 l/min; Max. working pressure: 16 bar; Nominal fan speed: 1200 1/min; Line voltage: 460 V; Line frequency: 60 Hz; Degree of protection: IP55; Motor efficiency class: IE2; Rated power supply: Fan motor: 0.21 kW at 60 Hz; |
------ |
|
2AT0430-0PL32-6QP1 |
16 |
FLENDER Oil supply system; Cooling unit with ext. pump; Type: OLOO, Size: 2; Coolant: air; Installation: Base frame, Steel; Oil flow rate: acc. to external pump: min. 5 l/min, max. 70 l/min; Max. working pressure: 16 bar; Nominal fan speed: 1200 1/min; Line voltage: 400 V; Line frequency: 50 Hz; Degree of protection: IP55; Motor efficiency class: IE2; Rated power supply: Fan motor: 0.25 kW at 50 Hz; |
------ |
|
2AT0430-0SU63-3UE8 |
16 |
FLENDER Oil supply system; Cooling unit with ext. pump; Type: OLOO, Size: 2; Coolant: air; Installation: Base frame, Steel; Oil flow rate: acc. to external pump: min. 5 l/min, max. 70 l/min; Max. working pressure: 16 bar; Nominal fan speed: 1200 1/min; Line voltage: 460 V; Line frequency: 60 Hz; Degree of protection: IP55; Motor efficiency class: IE2; Rated power supply: Fan motor: 0.29 kW at 60 Hz; |
------ |
|
2AT0430-0WE04-0XV6 |
16 |
FLENDER Oil supply system; Cooling unit with ext. pump; Type: OLOO, Size: 2; Coolant: air; Installation: Base frame, Steel; Oil flow rate: acc. to external pump: min. 5 l/min, max. 70 l/min; Max. working pressure: 16 bar; Nominal fan speed: 1200 1/min; Line voltage: 400 V; Line frequency: 50 Hz; Degree of protection: IP55; Motor efficiency class: IE2; Rated power supply: Fan motor: 0.18 kW at 50 Hz; |
------ |
|