Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
1FN3450-4WB00-0AA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=3860N; Fmax=10350N; Vmax FN=164m/min; Vmax Fmax=62 m/min; In=23.8A; Imax=70.3A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3450-4WB00-0BA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=3860N; Fmax=10350N; Vmax FN=164m/min; Vmax Fmax=62 m/min; In=23.8A; Imax=70.3A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3450-4WB50-0AA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=3860N; Fmax=10350N; Vmax FN=217m/min; Vmax Fmax=90m/min; In=30.4A; Imax=89.8A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3450-4WB50-0BA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=3860N; Fmax=10350N; Vmax FN=217m/min; Vmax Fmax=90m/min; In=30.4A; Imax=89.8A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3450-4WC00-0AA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=3860N; Fmax=10350N; Vmax FN=275m/min; Vmax Fmax=120m/min; In=37.5A; Imax=110.6A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3450-4WC00-0BA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=3860N; Fmax=10350N; Vmax FN=275m/min; Vmax Fmax=120m/min; In=37.5A; Imax=110.6A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3450-4WE00-0AA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=3860N; Fmax=10350N; Vmax FN=519m/min; Vmax Fmax=240 m/min; In=67.6A; Imax=199.5A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3450-4WE00-0BA3 |
31.7 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=3860N; Fmax=10350N; Vmax FN=519m/min; Vmax Fmax=240 m/min; In=67.6A; Imax=199.5A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-2NB80-0BA3 |
28.9 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Continuous load model; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; with FN=3460N; Fmax=5870N; Vmax FN=200m/min; Vmax Fmax=112m/min; In=28.4A; Imax=59.4A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-2WA50-0AA3 |
22.5 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=2610N; Fmax=6900N; Vmax FN=120m/min; Vmax Fmax=36m/min; In=12.4A; Imax=36A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-2WA50-0BA3 |
22.5 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=2610N; Fmax=6900N; Vmax FN=120m/min; Vmax Fmax=36m/min; In=12.4A; Imax=36A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-2WB00-0AA3 |
22.5 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=2610N; Fmax=6950N; Vmax FN=168m/min; Vmax Fmax=66m/min; In=15.4A; Imax=45.6A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-3NB80-0BA3 |
44.3 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Continuous load model; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; with FN=5185N; Fmax=8810N; Vmax FN=199 m/min; Vmax Fmax=111 m/min; In=42.5A; Imax=89.5A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-3WB00-0AA3 |
33.5 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=3915N; Fmax=10350N; Vmax FN=155m/min; Vmax Fmax=58m/min; In=23.2A; Imax=67.3A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-3WB00-0BA3 |
33.5 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=3915N; Fmax=10350N; Vmax FN=155m/min; Vmax Fmax=58m/min; In=23.2A; Imax=67.3A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-3WC00-0AA3 |
33.5 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=3915N; Fmax=10350N; Vmax FN=254m/min; Vmax Fmax=112m/min; In=35.2A; Imax=102.4A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-3WC00-0BA3 |
33.5 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=3915N; Fmax=10350N; Vmax FN=254m/min; Vmax Fmax=112m/min; In=35.2A; Imax=102.4A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-4NA70-0BA3 |
58.2 |
SIMOTICS L Primary section for linear motor; Component 3-phase synchronous motor; Continuous load model; 2-temp. monitoring circuits with PTC and KTY; Connection via 2 cables (power and signal); Cover prepared for metric a cable gland; FN=6915N; Fmax=11740N; Vmax FN=85m/min; Vmax Fmax=43m/min In=26.3A; Imax=55.3A direct motors, observe national and international license conditions, SO THAT NO INFRINGEMENTS occur with PTC120 and Temperature sensor Pt1000 |
------ |
|
1FN3600-4NB80-0BA3 |
58.2 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Continuous load model; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; with FN=6915N; Fmax=1170N; Vmax FN=199m/min; Vmax Fmax=111m/min; In=56.7A; Imax=119.3A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-4WA30-0AA3 |
43 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=5220N; Fmax=13800N; Vmax FN=105m/min; Vmax Fmax=26 m/min; In=22.3 A; Imax=64.9A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-4WA30-0BA3 |
43 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=5220N; Fmax=13800N; Vmax FN=105m/min; Vmax Fmax=26 m/min; In=22.3 A; Imax=64.9A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-4WB00-0AA3 |
43 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=5220N; Fmax=13800N; Vmax FN=155m/min; Vmax Fmax=58 m/min; In=30.9A; Imax=89.8A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-4WB00-0BA3 |
43 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=5220N; Fmax=13800N; Vmax FN=155m/min; Vmax Fmax=58 m/min; In=30.9A; Imax=89.8A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-4WB50-0AA3 |
43 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=5220N; Fmax=13800N; Vmax FN=215 m/min; Vmax Fmax=91 m/min; In=40.8 A; Imax=118.5A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|
1FN3600-4WB50-0BA3 |
43 |
SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=5220N; Fmax=13800N; Vmax FN=215 m/min; Vmax Fmax=91 m/min; In=40.8 A; Imax=118.5A When using direct motors, observe the national and international license conditions, so that no infringements of property rights occur |
------ |
|