Обзор
Обзор
SIMOTION D Control Units are available in a range of performance variants. This ensures the highest degree of scalability and flexibility. The individual variants SIMOTION D425, SIMOTION D435 and SIMOTION D445 differ in terms of performance characteristics (Motion Control + PLC) and the following features:
|
SIMOTION D425
|
SIMOTION D435
|
SIMOTION D445
|
Maximum number of axes
|
16
|
32
|
64
|
DRIVE-CLiQ interfaces
|
4
|
4
|
6
|
Fan/battery module
|
Option
|
Option
|
required
|
Additional drives can be operated by means of PROFIBUS or PROFINET with the CU320 Control Units. Additional drives can also be directly connected to the SIMOTION D445 Control Unit by means of DRIVE-CLiQ with the SIMOTION CX32 module.
The drives can operate in Servo, Vector or V/f control mode.
Заказные данные
Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
6AU1425-0AA00-0AA0 |
3.1 |
Simotion на базе привода control unit d425 нижний диапазон мощностей до 16 mc-осей на плате 8di / 8dio |
------ |
|
6AU1435-0AA00-0AA1 |
3.1 |
Simotion на базе привода control unit d435 сред. диапазон мощностей |
------ |
|
6AU1445-0AA00-0AA0 |
4 |
Simotion на базе привода control unit d445 верхний диапазон мощностей до 64 mc-осей на плате 8di / 8dio |
------ |
|
Аксессуары
Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
6FC5247-0AA18-0AA0 |
0.019 |
SINUMERIK БАТАРЕЯ ДЛЯ MMC, NCU, CCU И MCI-BOARD |
------ |
|
6FC5348-0AA01-0AA0 |
0.11 |
SIMOTION / SINUMERIK МОДУЛЬ ВЕНТИЛЯТОРА/БАТАРЕМ МАЛЕНЬКИЙ ВЕНТИЛЯТОР ВНЕШНЕЕ ОХЛАЖДЕНИЕ ВКЛ. БУФЕРНУЮ БАТАРЕЮ NCU710/NCU720/NNCU730 D425/D435 (ОПЦИЯ) D445 (ЗАПАСНАЯ ЧАСТЬ) |
------ |
|
6SL3064-1BB00-0AA0 |
0.14 |
SINAMICS/SINUMERIK РАСПОРНЫЙ ДЕРЖАТЕЛЬ ДЛЯ 50 ММ БЛОК УПРАВЛЕНИЯ CU320 ИЛИ NCU7X0 |
------ |
|
Тех. данные
Дизайн
Interfaces
- Displays, diagnostics
- LEDs to display operating states and errors
- 7-segment status/error display during system power-up
- 3 test sockets
- Interfaces
- 4 × DRIVE CLiQ (6 × DRIVE CLiQ for SIMOTION D445)
- 2 x Industrial Ethernet
- 2 × PROFIBUS DP
- Integrated I/Os
- 8 digital inputs
- 8 digital inputs/outputs
- Various
- Terminals for 24 V electronics power supply
- Slot (Option slot) to receive a terminal expansion or additional communications ports
Data storage/data backup
SIMOTION D425, D435 and D445 Control Units have 320 KB of non-volatile SRAM (battery-backed for at least 5 days) for process variable storage. There are two options for storing data for a longer period:
- System commands for storing data on the SIMOTION CompactFlash card (CF)
- Use of a battery module
The CompactFlash card stores the runtime software and the user data and programs.
I/O
PROFIBUS DP
- Certified PROFIBUS standard slaves (DP/V0, DP/V1, DP/V2)
- SIMATIC ET 200S/M/X/eco/pro distributed I/O systems
DRIVE-CLiQ
- Modules from the SINAMICS range
- DRIVE-CLiQ cables, which are required to connect Line/Motor Modules to SIMOTION D, are supplied with the Line/Motor Modules (standard length).
Интеграция
Overview of SIMOTION D425, D435, D445 connections
The maximum permissible cable lengths should be taken into account when planning the cable layout.
Malfunctions may occur if longer lengths are used.
The permissible length of PROFIBUS DP cables depends on the configuration.
Технические данные
|
|
SIMOTION D425 Control Unit
Basic Performance
|
SIMOTION D435 Control Unit
Standard Performance
|
SIMOTION D445 Control Unit
High Performance
|
Power supply
|
|
|
|
|
|
V DC
|
24
|
24
|
24
|
|
V
|
20.4 to 28.8
|
20.4 to 28.8
|
20.4 to 28.8
|
Current consumption (at 24 V DC), not taking into account digital outputs, typ.
|
A
|
0.6
|
0.6
|
2
|
Inrush current, typ.
|
A
|
6
|
6
|
6
|
Power loss
|
W
|
15
|
15
|
50
|
Permissible ambient temperature
|
|
|
|
|
|
°C
|
– 40 to + 70
|
– 40 to + 70
|
– 40 to + 70
|
|
°C
|
0 to +55
|
0 to +55
|
0 to +55
|
Permissible relative humidity
(without condensation)
|
%
|
5 to 95
|
5 to 95
|
5 to 95
|
Air pressure
|
hPa
|
700 to 1060
|
700 to 1060
|
700 to 1060
|
Degree of protection to IEC 529
|
|
IP20
|
IP20
|
IP20
|
Width
|
mm
|
50 (1.97 in)
|
50 (1.97 in)
|
50 (1.97 in)
|
Height
|
mm
|
380 (14.96 in)
|
380 (14.96 in)
|
380 (14.96 in)
|
Depth
|
mm
|
230 (9.1 in)
|
230 (9.1 in)
|
270 (10.6 in)
|
Weight
|
|
|
|
|
|
kg
|
2,5 (5 lb)
|
2,5 (5 lb)
|
3,6 (8 lb)
|
|
g
|
7 (0.02 lb)
|
7 (0.02 lb)
|
7 (0.02 lb)
|
Digital inputs
|
|
8
|
8
|
8
|
Rated value
|
V DC
|
24
|
24
|
24
|
|
V
|
15 to 30
|
15 to 30
|
15 to 30
|
|
V
|
– 3 to + 5
|
– 3 to + 5
|
– 3 to + 5
|
Isolation
|
|
Yes, in groups of 4
|
Yes, in groups of 4
|
Yes, in groups of 4
|
Current consumption at 24 V,
typ. for signal level 1
|
mA
|
10
|
10
|
10
|
Signal propagation delays
|
µs
|
100
|
100
|
100
|
Digital inputs/outputs (parameterizable)
|
|
8
|
8
|
8
|
When used as an input
|
|
|
|
|
|
|
|
|
|
|
V DC
|
24
|
24
|
24
|
|
V
|
15 to 30
|
15 to 30
|
15 to 30
|
|
V
|
– 3 to + 5
|
– 3 to + 5
|
– 3 to + 5
|
|
|
No
|
No
|
No
|
- Current consumption at 24 V,
typ. for signal level 1
|
mA
|
10
|
10
|
10
|
- Signal propagation delays
|
µs
|
100 (1 µs as measuring probe)
|
100 (1 µs as measuring probe)
|
100 (1 µs as measuring probe)
|
When used as an output
|
|
|
|
|
|
V DC
|
24
|
24
|
24
|
|
V
|
20.4 to 28.8
|
20.4 to 28.8
|
20.4 to 28.8
|
|
|
|
|
|
|
V
|
15 to 30
|
15 to 30
|
15 to 30
|
|
|
No
|
No
|
No
|
|
mA
|
500 per output
|
500 per output
|
500 per output
|
|
mA
|
2
|
2
|
2
|
- Switching frequency of the outputs
|
|
|
|
|
|
Hz
|
100
|
100
|
100
|
|
Hz
|
2
|
2
|
2
|
|
|
yes
|
yes
|
yes
|
Real-time clock/SRAM backup
|
|
|
|
|
|
|
5 days
|
5 days
|
5 days
|
|
|
Only a few minutes
|
Only a few minutes
|
Only a few minutes
|
Approvals
|
|
cULus (File No.: E164110)
|
cULus (File No.: E164110)
|
cULus (File No.: E164110)
|
Дальнейшая информация
Further information
- on PROFIBUS DP and Industrial Ethernet can be found in Catalog IK PI or in the Interactive Catalog under "Automation Systems/SIMATIC NET Communication Systems“ and under "Communication".
- on the SIMOTION Motion Control System Catalog PM10 can be found
|
|