Обзор
The LZX complete units and accessory parts previously available are no longer listed in this catalog. They can still be supplied however in limited quantities. In their place you will now find the new LZS types. LZS complete units are fully compatible with their predecessors, the LZX complete units. The LZX plug-in relays have not been changed and are used accordingly in both the LZS and the LZX series.
Due to differences in geometry the LED modules, plug-in bases, retaining brackets and labels can be combined and/or used in only the respective series, LZS or LZX.
Prices for the new LZS series are lower than for the previous LZX series. In addition the LZS series offers not only service-proven screw connections but also versions with push-in terminals.
The following conversion list will help you to change over from the LZX types previously sold to the new LZS types. Please contact your regional adviser if you have any questions.
List for converting from LZX to LZS relay couplers:
Complete units
Previous Order No.
|
New Order No.
|
LZX:PT3A5L24
|
LZS:PT3A5L24
|
LZX:PT3A5R24
|
LZS:PT3A5R24
|
LZX:PT3A5S15
|
LZS:PT3A5S15
|
LZX:PT3A5T30
|
LZS:PT3A5T30
|
LZX:PT5A5L24
|
LZS:PT5A5L24
|
LZX:PT5A5R24
|
LZS:PT5A5R24
|
LZX:PT5A5S15
|
LZS:PT5A5S15
|
LZX:PT5A5T30
|
LZS:PT5A5T30
|
LZX:PT5B5L24
|
LZS:PT5B5L24
|
LZX:PT5B5R24
|
LZS:PT5B5R24
|
LZX:PT5B5S15
|
LZS:PT5B5S15
|
LZX:PT5B5T30
|
LZS:PT5B5T30
|
LZX:RT3A4L24
|
LZS:RT3A4L24
|
LZX:RT3A4R24
|
LZS:RT3A4R24
|
LZX:RT3A4S15
|
LZS:RT3A4S15
|
LZX:RT3A4T30
|
LZS:RT3A4T30
|
LZX:RT3B4L24
|
LZS:RT3B4L24
|
LZX:RT3B4R24
|
LZS:RT3B4R24
|
LZX:RT3B4S15
|
LZS:RT3B4S15
|
LZX:RT3B4T30
|
LZS:RT3B4T30
|
LZX:RT4A4L24
|
LZS:RT4A4L24
|
LZX:RT4A4R24
|
LZS:RT4A4R24
|
LZX:RT4A4S15
|
LZS:RT4A4S15
|
LZX:RT4A4T30
|
LZS:RT4A4T30
|
LZX:RT4B4L24
|
LZS:RT4B4L24
|
LZX:RT4B4R24
|
LZS:RT4B4R24
|
LZX:RT4B4S15
|
LZS:RT4B4S15
|
LZX:RT4B4T30
|
LZS:RT4B4T30
|
List for converting from LZX to LZS accessories for individual modules:
Complete units
Previous Order No.
|
New Order No.
|
LZX:MT28800
|
LZS:MT28800
|
LZX:MT78750
|
LZS:MT78750
|
LZX:PT16016
|
LZS:PT170241)
LZS:PT170212)
|
LZX:PT16040
|
LZS:PT17040
|
LZX:PT78702
|
LZS:PT78720
|
LZX:PT78703
|
LZS:PT78730
|
LZX:PT78704
|
LZS:PT78740
|
LZX:PT78802
|
LZS:PT78722
|
LZX:PT78804
|
LZS:PT78742
|
LZX:RPMG0024
|
LZS:PTMG0024
|
LZX:RPMG0524
|
LZS:PTMG0524
|
LZX:RPMG0730
|
LZS:PTMG0730
|
LZX:RPML0024
|
LZS:PTML0024
|
LZX:RPML0524
|
LZS:PTML0524
|
LZX:RPML0730
|
LZS:PTML0730
|
LZX:RPMT00A0
|
LZS:PTMT00A0
|
LZX:RPMU0548
|
LZS:PTMU0524
|
LZX:RPMU0730
|
LZS:PTMU0730
|
LZX:RT16016
|
LZS:RT17016
|
LZX:RT78625
|
LZS:RT78725
|
LZX:RT78626
|
LZS:RT78726
|
LZX:RY16040
|
LZS:RT17040
|
1) LZS:PT17024 for PT standard base: Without logical isolation, screw terminals.
2) LZS:PT17021 for PT standard base with logical isolation, screw terminals and push-in terminals.
Тех. данные
Дизайн
Plug-in relay coupling links can be ordered complete or as single modules.
Mounting
The relays are plugged into the base and this is snapped onto a TH 35 standard mounting rail according to EN 60715.
A fixing bracket can be ordered for the MT series that additionally fixes the relay into a plug-in base (under conditions of increased mechanical stress). For the RT and PT series, a combined fixing and ejection bracket is available which can be used to disassemble the relay where access is difficult, for example, when relays are mounted side-by-side.
They can be mounted as required.
Функции
In accordance with the technical specifications of electronic systems, the coupling links have a lower power consumption. In the versions equipped with LEDs, these indicate the switching state. The LZS: PT/MT relay couplers have a test button. This can be used to force the relay coupler into the switching state and to lock it. This is indicated by a raised orange-colored lever.
Surge suppression
The 24 V DC relays LZX:RT and LZX: PT with LEDs can be supplied with, all others without integral surge suppression (freewheel diode connected in parallel with A1/A2). The positive supply voltage must be connected to coil terminal A1.
Logical disconnection
The terminals for the contacts and the terminals for the coil are arranged on separate levels, e.g. above for contacts and below for coil. Logical isolation is not necessarily safe isolation.
Safe isolations
For safe isolation, transfer of the voltage of one circuit to another circuit is prevented to a suitable degree of safety (requirements and tests are described in EN 60947-1 in Appendix N).
Control with solid-state output
In the case of solid-state outputs (e.g. BERO) with overload and short-circuit protection, you must make allowance during configuration for the temporarily flowing capacitor charging currents!
This is possible, for example, by using a suitable LZS relay coupler.

Дополнительную информацию вы можете получить загрузив
файл в формате PDF (167797 байт).
Технические данные

Дополнительную информацию вы можете получить загрузив
файл в формате PDF (537316 байт).
Чертеж

Дополнительную информацию вы можете получить загрузив
файл в формате PDF (213883 байт).
Дальнейшая информация