Switch ES Power
Adjustment of parameter set A with Switch ES Power
Switch ES Power is the shared software platform for communication-capable SENTRON circuit breakers. This has the advantage that all device-specific setting options are identical in terms of appearance and handling.
Switch ES Power can be used to configure, document, operate and monitor the SENTRON 3WL and SENTRON 3VL circuit breakers through PROFIBUS DP.
Заказные данные
Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
3ZS2311-0CC10-0YA0 |
0.2 |
Принадлежность автоматических выключателей 3wl/3vl switch es power software zum parametr. и diagnostizieren von sentron vl и wl ueber den profibus dp |
------ |
|
Тех. данные
Особенности
Switch ES Power
- Parameterization, documentation, operation and monitoring in one software
- Documentation of measured values and settings
- Clear presentation of all available parameters
- All the available status information and measured values are clearly displayed in dialog boxes
- One software for SENTRON 3WL and SENTRON 3VL
- Easy connection build-up through acyclic PROFIBUS DP-V1 data traffic
- Identical storage format for parameters with the Breaker Data Adapter (BDA)
- Easy-to-operate Windows interface
- No programming knowhow is required for operation
Object manager of Switch ES Power
- Uniform data management for circuit breaker parameters
- Automatic parameterization if components are replaced
Дизайн
Switch ES Power
The design of both the data tree and the individual data windows has been cross-referenced and harmonized with the structure of the Breaker Data Adapter. As a result, the same functions and information are available. Due to its support of the innovative PROFIBUS DPV1 function, it is particularly easy to link up a computer to the PROFIBUS using Switch ES Power. Simply connect, select the PROFIBUS address and start communications, even if the SENTRON circuit breakers are simultaneously exchanging data with another station (e.g. S7) via the PROFIBUS.
With Switch ES Power, it is also possible to create parameter sets offline without a direct connection to the circuit breaker. These parameter sets can then be transmitted to the SENTRON circuit breakers in the plant at a later stage.
Функции
Online functions with Switch ES Power
The Switch ES Power is used to load and display the control identification data. Depending on the circuit breaker configuration, the parameters for the protection function (LSING), the extended protection function, the configurable threshold values, the communication, and the configurable output module are displayed. These can be modified accordingly and loaded and stored on the switching device. Various online dialog boxes are available depending on the type of circuit breaker:
- main view
- diagnostics window
- measured values window
- window for displaying the harmonic analysis
- window for displaying the curve form memory
- dialog box for maintenance and statistics
The memory formats of the BDA and Switch ES Power are identical, which means that it is for example possible to generate central parameter files with Switch ES Power and then copy them to a notebook with the BDA for use by service personnel.
Switch ES Power supports all PROFIBUS cards for the Siemens PC/notebook. Some cards require an additional software package (driver); for more details refer to the interactive Catalog CA 01.
Интеграция
Object Manager of Switch ES Power
The Object Manager (OM) of Switch ES Power is used for the integration of Switch ES Power into STEP 7 environment, and therefore also into Totally Integrated Automation (TIA) environment. This allows Switch ES Power to be invoked from the HWConfig Tool from STEP 7, and the SENTRON 3WL/3VL circuit breakers to be configured. This data is then stored in the STEP 7 database and automatically transferred to the device during start-up (SPS, Slave) of the PROFIBUS DP.
Setting of the parameter set A with Switch ES Power
Online functions with Switch ES Power