Обзор

Обзор



SIRIUS 3SK1 safety relays are the key elements of a consistent, cost-effective safety chain. Whether you need EMERGENCY-STOP disconnection, protective door monitoring, light arrays, laser scanners or the protection of presses or punches – with SIRIUS safety relays 22.5 mm wide every safety application can be implemented to optimum effect in terms of engineering and price.

The following safety-related functions are available:

  • Monitoring the safety functions of sensors
  • Monitoring the sensor leads
  • Monitoring correct functioning of safety relays
  • Monitoring the actuators in the shutdown circuit
  • Safety-related disconnection when dangers arise

SIRIUS 3SK1 safety relays are approved for applications up to SIL 3 (IEC 61508/IEC 62061) or PL e (EN ISO 13849-1).

SIRIUS 3SK1 safety relays stand out due to their flexibility for both parameterization and system designs with several evaluation units. Optimized solutions when selecting components are facilitated by a clearly structured component range:

  • Standard basic units
  • Advanced basic units
  • Output expansions
  • Input expansions
  • Accessories

The 3SK1 Standard basic units are characterized by the following features:

  • Compact design
  • Simple operation
  • Relay and semiconductor outputs
  • Economical solution

However, the 3SK1 Advanced basic units also offer the following:

  • Universal application opportunities thanks to multifunctionality
  • Time-delayed outputs
  • Expansion of inputs and outputs

In the case of Advanced basic units, the 3ZY1 device connector allows safety functions involving several sensors and actuators to be constructed very quickly.

System configuration example

The 3SK1 Standard and Advanced series are a high-quality replacement for the 3TK28 safety relays. In their narrower design, and equipped with greater functionality, they can replace every 3TK28 device. The only exceptions are devices with special functions, such as 3TK2826, 3TK2845 and the 3TK2810 devices. See below for a conversion table from 3TK28 to 3SK1.

Note:

For the conversion table, e.g. from 3TK28 to 3SK1, see below or the conversion tool http://www.siemens.com/sirius/conversion-tool.

Functional overview of the 3SK1 series

Type

Standard basic units

Advanced basic units

 

Relay enabling circuits

Solid-state enabling circuits

Relay enabling circuits

Solid-state enabling circuits

Sensors

  • Mechanical

  • Single-ended

1)

  • Antivalent

--

--

  • Expandable

--

✓ by means of cascading

Parameter

  • Start (auto/monitored)

  • Sensor connection, 2 x 1-channel/
    1 x 2-channel

✓ Using wiring

  • Crossover monitoring

✓ Using wiring

  • Start test ON/OFF

--

  • Monitoring of two-hand operator panels acc. to EN 574

--

--

Enabling circuits

  • Instantaneous

  • Time-delayed

--

--

  • Expandable with relay enabling circuits

✓ Using wiring

✓ Using wiring

  • Device connectors

--

--

Rated control supply voltage

  • 24 V DC

2)

  • 115 … 240 V AC/DC

--

3)

3)


✓ Available

-- Not available

1) 24 V basic units only.

2) 24 V AC/DC.

3) Possible using 3SK1230 power supply via device connector.

3SK112 and 3SK1112 safety relays with DIP switch

The 3SK112 and 3SK1112 safety relays are configurable safety relays. They are used as evaluation units for typical safety chains (detect, evaluate, respond). A number of functions can be set using the DIP switches on the front. Thus the 3SK112 and 3SK1112 can be used universally.

DIP switch No.

OFF

ON

Circuit diagram

1

Autostart sensor input

Monitored start sensor input

 

2

without crossover monitoring

With crossover monitoring

3

2 x single-channel sensor connection

1 x 2-channel sensor connection

4

with start test

without start test


Innovative enclosure concept for the SIRIUS 3SK1 safety relays

Can be expanded by adding the 3RM1 motor starter

With previous safety relay and motor starter designs an enormous amount of wiring was required to monitor the motor starters in safety applications.

Traditional system design

With the integration of the SIRIUS 3RM1 motor starter into the SIRIUS 3SK1 safety relay system family, this wiring has been minimized for the first time.

Motors up to 3 kW can easily be integrated into the safety relay system using SIRIUS 3ZY1 device connectors, without having to run a cable between the evaluation unit and the motor starter.

3SK1 and 3RM1 system design

Conversion table

The table below lists the existing 3TK28 article numbers with the corresponding 3SK1 article numbers.

Article number
3TK28 basic units

Article number
3SK1 Standard basic units

Article number
3SK1 Advanced basic units

3TK2820

3TK2820-1AJ20

3SK1111-1AW20

3SK1121-1AB40 + 3SK1230-1AW20

3TK2820-1AL20

3SK1111-1AW20

3SK1121-1AB40 + 3SK1230-1AW20

3TK2820-1CB30

3SK1111-1AB30

3SK1121-1AB40

3TK2820-2AJ20

3SK1111-2AW20

3SK1121-2AB40 + 3SK1230-2AW20

3TK2820-2AL20

3SK1111-2AW20

3SK1121-2AB40 + 3SK1230-2AW20

3TK2820-2CB30

3SK1111-2AB30

3SK1121-2AB40

3TK2821

3TK2821-1CB30

3SK1111-1AB30

3SK1121-1AB40

3TK2821-2CB30

3SK1111-2AB30

3SK1121-2AB40

3TK2822

3TK2822-1CB30

3SK1111-1AB30

3SK1121-1AB40

3TK2822-2CB30

3SK1111-2AB30

3SK1121-2AB40

3TK2823

3TK2823-1CB30

3SK1111-1AB30

3SK1121-1AB40

3TK2823-2CB30

3SK1111-2AB30

3SK1121-2AB40

3TK2824

3TK2824-1AJ20

3SK1111-1AW20

3SK1121-1AB40 + 3SK1230-1AW20

3TK2824-1AL20

3SK1111-1AW20

3SK1121-1AB40 + 3SK1230-1AW20

3TK2824-1BB40

3SK1111-1AB30

3SK1121-1AB40

3TK2824-1CB30

3SK1111-1AB30

3SK1121-1AB40

3TK2824-2AJ20

3SK1111-2AW20

3SK1121-2AB40 + 3SK1230-2AW20

3TK2824-2AL20

3SK1111-2AW20

3SK1121-2AB40 + 3SK1230-2AW20

3TK2824-2BB40

3SK1111-2AB30

3SK1121-2AB40

3TK2824-2CB30

3SK1111-2AB30

3SK1121-2AB40

3TK2825

3TK2825-1AB20

3SK1111-1AW20

3SK1121-1AB40 + 3SK1230-1AW20

3TK2825-1AJ20

3SK1111-1AW20

3SK1121-1AB40 + 3SK1230-1AW20

3TK2825-1AL20

3SK1111-1AW20

3SK1121-1AB40 + 3SK1230-1AW20

3TK2825-1BB40

3SK1111-1AB30

3SK1121-1AB40

3TK2825-2AB20

3SK1111-2AW20

3SK1121-2AB40 + 3SK1230-2AW20

3TK2825-2AJ20

3SK1111-2AW20

3SK1121-2AB40 + 3SK1230-2AW20

3TK2825-2AL20

3SK1111-2AW20

3SK1121-2AB40 + 3SK1230-2AW20

3TK2825-2BB40

3SK1111-2AB30

3SK1121-2AB40

3TK2827

3TK2827-1AB20

--

--

3TK2827-1AB21

--

Область применения



SIRIUS 3SK1 safety relays are used mainly in autonomous safety applications which are not connected to a safety-oriented bus system. Their function here is to evaluate the sensors and the safety-oriented shutdown of hazards. Also they check and monitor the sensors, actuators and safety-oriented functions of the safety relay.