Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
3VA2510-5HM42-0AA0 |
16.78 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 4-pole, system protection ETU330, LIG, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Ii=1.5...10 x In N-conductor protection adjustable (OFF, 50%, 100%) Ground fault protection Ig=0.2...1 x In= tg=0.1/0.3s Lug terminal |
------ |
|
3VA2510-5HN32-0AA0 |
14.152 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal |
------ |
|
3VA2510-5HN32-0AB0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 2 auxiliary switches HP |
------ |
|
3VA2510-5HN32-0AC0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 2 auxiliary switches HQ |
------ |
|
3VA2510-5HN32-0AD0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 3 auxiliary switches HQ |
------ |
|
3VA2510-5HN32-0AE0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 4 auxiliary switches HQ |
------ |
|
3VA2510-5HN32-0AF0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 1 auxiliary switch HQ 1 tripped signaling contact HQ |
------ |
|
3VA2510-5HN32-0AG0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 1 auxiliary switch HP 1 tripped signaling contact HP |
------ |
|
3VA2510-5HN32-0AH0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2510-5HN32-0AJ0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal 2 auxiliary switches HP 1 tripped signaling contact HP |
------ |
|
3VA2510-5HN32-0BA0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 24V DC |
------ |
|
3VA2510-5HN32-0BC0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 24 V DC 2 auxiliary switches HQ |
------ |
|
3VA2510-5HN32-0BH0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 24 V DC 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2510-5HN32-0BL0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 24 V DC 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective trip unit signaling switch |
------ |
|
3VA2510-5HN32-0CA0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 120-127V AC 50/60Hz |
------ |
|
3VA2510-5HN32-0CC0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 120-127 V AC 50/60 Hz 2 auxiliary switches HQ |
------ |
|
3VA2510-5HN32-0CH0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 120-127 V AC 50/60 Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ |
------ |
|
3VA2510-5HN32-0CL0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 120-127 V AC 50/60 Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective trip unit signaling switch |
------ |
|
3VA2510-5HN32-0DA0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 208-230 V AC 50/60 Hz |
------ |
|
3VA2510-5HN32-0DC0 |
14.2 |
Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU350, LSI, In=1000 A Overload protection Ir=400 A...1000 A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In Lug terminal Undervoltage release (UVR) 208-230 V AC 50/60 Hz 2 auxiliary switches HQ |
------ |
|
5TT4437-5 |
0.141 |
ДИСТАНЦИОННЫЙ ВЫКЛЮЧАТЕЛЬ 1ПК 25А 24В DC |
------ |
|
5TT4451-5 |
0.137 |
ДИСТАНЦИОННЫЙ ВЫКЛЮЧАТЕЛЬ 1НО 32А 24В DC |
------ |
|
5TT4452-0 |
0.145 |
ДИСТАНЦИОННЫЙ ВЫКЛЮЧАТЕЛЬ 2НО 32А 230/230В AC |
------ |
|
5TT4452-2 |
0.146 |
ДИСТАНЦИОННЫЙ ВЫКЛЮЧАТЕЛЬ 2НО 32А 24/24В AC |
------ |
|
5TT4452-5 |
0.147 |
ДИСТАНЦИОННЫЙ ВЫКЛЮЧАТЕЛЬ 2НО 32А 24В DC |
------ |
|