(LV10)

В этой рубрике 2569 кодов.

Страницы: [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] [34] [35] [36] [37] [38] [39] [40] [41] [42] [43] [44] [45] [46] [47] [48] [49] [50] [51] [52] [53] [54] [55] [56] [57] [58] [59] [60] [61] [62] [63] [64] [65] [66] [67] [68] [69] [70] [71] [72] [73] [74] [75] [76] [77] [78] [79] [80] [81] [82] [83] [84] [85] [86] [87] [88] [89] [90] [91] [92] [93] [94] [95] [96] [97] [98] [99] [100] [101] [102] [103]
Заказной № Вес, кг Описание Наличие на складе Заказать
3VA2580-5JP32-0DC0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Undervoltage release (UVR) 208-230 V AC 50/60 Hz 2 auxiliary switches HQ ------
3VA2580-5JP32-0DH0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Undervoltage release (UVR) 208-230 V AC 50/60 Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ ------
3VA2580-5JP32-0DL0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Undervoltage release (UVR) 208-230 V AC 50/60 Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective tripping signaling switch ------
3VA2580-5JP32-0HA0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 12-30 V DC; 24V AC 50/60Hz ------
3VA2580-5JP32-0HC0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 12-30 V DC; 24V AC 50/60Hz 2 auxiliary switches HQ ------
3VA2580-5JP32-0HH0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 12-30 V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ ------
3VA2580-5JP32-0HL0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 12-30 V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective tripping signaling switch ------
3VA2580-5JP32-0JA0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC ------
3VA2580-5JP32-0JC0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC 2 auxiliary switches HQ ------
3VA2580-5JP32-0JH0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC 2 auxiliary switches HQ 1 tripped signaling contact HQ ------
3VA2580-5JP32-0JL0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 110-127 V DC, 50/60 Hz AC 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective tripping signaling switch ------
3VA2580-5JP32-0KA0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 220-250 V DC; 208-277V AC ------
3VA2580-5JP32-0KC0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 220-250 V DC; 208-277V AC 2 auxiliary switches HQ ------
3VA2580-5JP32-0KH0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 220-250 V DC; 208-277V AC 2 auxiliary switches HQ 1 tripped signaling contact HQ ------
3VA2580-5JP32-0KL0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Lug terminal Shunt release (STL) 220-250 V DC; 208-277V AC 2 auxiliary switches HQ 1 tripped signaling contact HQ 1 protective tripping signaling switch ------
3VA2580-5JP42-0AA0 15.42 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 4-pole, system protection ETU550, LSI, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection adjustable (OFF, up to 160%) Lug terminal ------ Заказать
3VA2580-5KQ32-0AA0 14.035 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal ------ Заказать
3VA2580-5KQ32-0AB0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 2 auxiliary switches HP ------
3VA2580-5KQ32-0AC0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 2 auxiliary switches HQ ------
3VA2580-5KQ32-0AD0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 3 auxiliary switches HQ ------
3VA2580-5KQ32-0AE0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 4 auxiliary switches HQ ------
3VA2580-5KQ32-0AF0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 1 auxiliary switch HQ 1 tripped signaling contact HQ ------
3VA2580-5KQ32-0AG0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 1 auxiliary switch HP 1 tripped signaling contact HP ------
3VA2580-5KQ32-0AH0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 2 auxiliary switches HQ 1 tripped signaling contact HQ ------
3VA2580-5KQ32-0AJ0 14.2 Circuit breaker 3VA2 IEC Frame 1000 Switching capacity class M Icu=55 kA @ 415 V 3-pole, system protection ETU860, LSIG, In=800 A Overload protection Ir=320 A...800 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N-conductor protection optionally with external current transformer, up to 160% Ground fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s Lug terminal 2 auxiliary switches HP 1 tripped signaling contact HP ------
Неверный логин или пароль!
Зарегистрироваться
Оформить заказ
Очистить
Корзина
почта: info@teslacom.ru
тел./факс: 8 (495) 229-56-79
OOO «ТеслаКом» тел./факс (495)229-56-79, info@teslacom.ru
Top.Mail.Ru Яндекс.Метрика