3VT1701-2DC35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=16 A rated current IR=12.5...16 A overload protection II=160...240 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1701-2DM35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, motor protection Overcurrent release TM, LI In=16 A rated current IR=12.5...16 A overload protection II=160 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1701-2EC45-0AA0 |
0.99 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=16 A rated current IR=12.5...16 A overload protection II=160...240 A, Short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1702-2DC35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=20 A rated current IR=16...20 A overload protection II=200...300 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1702-2DM35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, motor protection Overcurrent release TM, LI In=20 A rated current IR=16...20 A overload protection II=200 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1702-2EC45-0AA0 |
0.99 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection overcurrent release TM, LI In=20 A rated current Ir=16...20 A overload protection II=200...300 A, short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front connections |
------ |
|
3VT1703-2DC35-0AA0 |
0.961 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=32 A rated current IR=25...32 A overload protection II=160...320 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1703-2DM35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, motor protection Overcurrent release TM, LI In=32 A rated current IR=25...32 A overload protection II=320 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1703-2EC45-0AA0 |
0.99 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=32 A rated current IR=25...32 A overload protection II=160...320 A, Short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1704-2DA35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=40 A rated current Ir=40 A overload protection II=160 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1704-2DC35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=40 A rated current IR=32...40 A overload protection II=200...400 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1704-2DM35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, motor protection Overcurrent release TM, LI In=40 A rated current IR=32...40 A overload protection II=400 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1704-2EA45-0AA0 |
0.99 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=40 A rated current Ir=40 A overload protection II=160 A, Short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1704-2EC45-0AA0 |
0.99 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=40 A rated current IR=32...40 A overload protection II=200...400 A, Short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1705-2DA35-0AA0 |
0.956 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=50 A rated current IR=50A overload protection II=200 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1705-2DC35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=50 A rated current IR=40...50 A overload protection II=250...500 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1705-2DM35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, motor protection Overcurrent release TM, LI In=50 A rated current IR=40...50 A overload protection II=500 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1705-2EA45-0AA0 |
0.99 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection overcurrent release TM, LI In=50 A rated current IR=50A overload protection II=200 A, short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front connections |
------ |
|
3VT1705-2EC45-0AA0 |
0.99 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection overcurrent release TM, LI In=50 A rated current Ir=40...50 A overload protection II=250...500 A, short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front connections |
------ |
|
3VT1706-2DA35-0AA0 |
0.952 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=63 A rated current IR=63A overload protection II=252 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1706-2DC35-0AA0 |
0.955 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=63 A rated current IR=50...63 A overload protection II=315...630 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1706-2DM35-0AA0 |
0.834 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, motor protection Overcurrent release TM, LI In=63 A rated current IR=50...63 A overload protection II=630 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1706-2EA45-0AA0 |
1.235 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=63 A rated current IR=63A overload protection II=252 A, Short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1706-2EC45-0AA0 |
1.228 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=63 A rated current IR=50...63 A overload protection II=315...630 A, Short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|
3VT1708-2DA35-0AA0 |
0.964 |
Circuit breaker 3VT1 Standard switching capacity Icu=25 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=80 A rated current IR=80A overload protection II=320 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch with front-side connections |
------ |
|