Обзор
Обзор
Preliminary selection of the motor according to motor type/series, speed or number of poles, frame size, rated output, rated torque, rated speed and rated current
Self-ventilated motors in Zone 1 with type of protection "e" (Ex e II Increased safety)
Speed
|
Frame size
|
Rated output
|
Rated speed
|
Rated torque
|
Rated current at 400 V
|
rpm
|
|
kW
|
rpm
|
Nm
|
A
|
Aluminum series 1MA7 50 Hz
|
3000, 2-pole
|
63 M ... 160 L
|
0.18 ... 16
|
2810 ... 2910
|
0.61 ... 53
|
0.55 ... 30.0
|
1500, 4-pole
|
63 M ... 160 L
|
0.12 ... 13.5
|
1375 ... 1465
|
0.83 ... 88
|
0.52 ... 27
|
1000, 6-pole
|
71 M ... 160 L
|
0.25 ... 9.7
|
850 ... 965
|
2.8 ... 96
|
0.81 ... 21
|
Cast-iron series 1MA6 50 Hz
|
3000, 2-pole
|
100 L ... 315 L
|
2.5 ... 165
|
2865 ... 2986
|
8.3 ... 528
|
5.3 ... 280
|
1500, 4-pole
|
100 L ... 315 L
|
2 ... 165
|
1420 ... 1492
|
14 ... 1061
|
4.5 ... 305
|
1000, 6-pole
|
100 L ... 315 L
|
1.3 ... 135
|
935 ... 991
|
13 ... 1300
|
3.35 ... 240
|
Self-ventilated motors in Zone 1 with type of protection "d" (Ex de IIC explosion-proof enclosure)
Speed
|
Frame size
|
Rated output
|
Rated speed
|
Rated torque
|
Rated current at 400 V
|
rpm
|
|
kW
|
rpm
|
Nm
|
A
|
Cast-iron series 1MJ6 50 Hz
|
3000, 2-pole
|
71 M ... 200 L
|
0.37 ... 37
|
2750 ... 2945
|
1 ... 120
|
0.98 ... 64
|
1500, 4-pole
|
71 M ... 200 L
|
0.25 ... 30
|
1325 ... 1465
|
1 ... 196
|
0.78 ... 55
|
1000, 6-pole
|
71 M ... 200 L
|
0.25 ... 22
|
870 ... 975
|
2 ... 215
|
0.82 ... 42.5
|
750, 8-pole
|
90 L ... 200 L
|
0.37 ... 15
|
655 ... 725
|
5 ... 198
|
1.16 ... 32
|
Cast-iron series 1MJ7 50 Hz
|
3000, 2-pole
|
225 M ... 315 M
|
45 ... 132
|
2955 ... 2980
|
145 ... 423
|
77 ... 225
|
1500, 4-pole
|
225 S ... 315 M
|
37 ... 132
|
1475 ... 1486
|
240 ... 848
|
67 ... 232
|
1000, 6-pole
|
225 M ... 315 M
|
30 ... 90
|
978 ... 988
|
293 ... 870
|
56 ... 162
|
750, 8-pole
|
225 S ... 315 M
|
18.5 ... 75
|
725 ... 738
|
244 ... 970
|
37.5 ... 140
|
Steel series 1MJ8 50 Hz
|
3000, 2-pole
|
355
|
315 ... 400
|
2982 ... 2985
|
1009 ... 1279
|
530 ... 655
|
1500, 4-pole
|
355
|
280 ... 400
|
1485 ... 1491
|
1795 ... 2561
|
495 ... 690
|
1000, 6-pole
|
355
|
250 ... 315
|
993 ... 994
|
2403 ... 3027
|
440 ... 560
|
750, 8-pole
|
355
|
200 ... 250
|
744
|
2566 ... 3206
|
370 ... 466
|
Steel/cast-iron series 1MJ1 50 Hz
|
3000, 2-pole
|
315 M ... 450
|
160 ... 900
|
2977 ... 2985
|
515 ... 2879
|
280 ... 915
|
1500, 4-pole
|
315 M ... 450
|
160 ... 950
|
1485 ... 1493
|
1030 ... 6076
|
285 ... 1355
|
1000, 6-pole
|
315 M ... 450
|
110 ... 800
|
990 ... 995
|
1060 ... 7676
|
195 ... 1240
|
750, 8-pole
|
315 M ... 450
|
90 ... 670
|
740 ... 746
|
1160 ... 8579
|
175 ... 1210
|
Self-ventilated motors in Zones 2, 21 and 22 with type of protection “n” or protection against dust explosions
Speed
|
Frame size
|
Rated output
|
Rated speed
|
Rated torque
|
Rated current at 400 V, 50 Hz
at 460 V, 60 Hz
|
rpm
|
|
kW at 50 Hz
HP at 60 Hz
|
rpm
|
Nm
|
A
|
Aluminum series 1LA7 and 1LA5 1) 50 Hz
|
3000, 2-pole
|
56 M2) ... 225 M
|
0.09 ... 45
|
2830 ... 2959
|
0.3 ... 145
|
0.26 ... 78
|
1500, 4-pole
|
56 M2) ... 225 M
|
0.06 ... 45
|
1350 ... 1470
|
0.42 ... 292
|
0.2 ... 80
|
1000, 6-pole
|
63 M ... 225 M
|
0.09 ... 30
|
850 ... 978
|
1 ... 293
|
0.44 ... 61
|
750, 8-pole
|
71 M ... 225 M
|
0.09 ... 22
|
630 ... 724
|
1.4 ... 290
|
0.36 ... 44.5
|
Aluminum series 1LA9
|
„High Efficiency“ 50 Hz
|
3000, 2-pole
|
56 M ... 200 L
|
0.09 ... 37
|
2830 ... 2950
|
0.3 ... 120
|
0.24 ... 64
|
1500, 4-pole
|
56 M ... 200 L
|
0.06 ... 30
|
1380 ... 1465
|
0.42 ... 196
|
0.22 ... 53
|
1000, 6-pole
|
90 S ... 200 L
|
0.75 ... 22
|
925 ... 975
|
7.7 ... 215
|
2 ... 45
|
For implementation in the North American market according to EPACT 60 Hz
|
3600, 2-pole
|
56 M ... 200 L
|
0.12 ... 50
|
3440 ... 3555
|
0.25 ... 100
|
0.23 ... 57
|
1800, 4-pole
|
56 M ... 200 L
|
0.08 ... 40
|
1715 ... 1770
|
0.33 ... 161
|
0.18 ... 47
|
1200, 6-pole
|
90 S ... 200 L
|
1 ... 30
|
1140 ... 1175
|
6.2 ... 182
|
1.78 ... 40
|
Cast-iron series 1LA6 and 1LG4 50 Hz
|
3000, 2-pole
|
100 L ... 315 L
|
3 ... 200
|
2890 ... 2982
|
9.9 ... 641
|
6.1 ... 325
|
1500, 4-pole
|
100 L ... 315 L
|
2.2 ... 200
|
1420 ... 1486
|
15 ... 1285
|
4.7 ... 340
|
1000, 6-pole
|
100 L ... 315 L
|
1.5 ... 160
|
925 ... 988
|
15 ... 1547
|
3.9 ... 285
|
750, 8-pole
|
100 L ... 315 L
|
0.75 ... 132
|
679 ... 738
|
11 ... 1708
|
2.15 ... 245
|
Cast-iron series 1LG6
|
„High Efficiency“ 50 Hz
|
3000, 2-pole
|
180 M ... 315 L
|
22 ... 200
|
2955 ... 2982
|
71 ... 641
|
38.5 ... 320
|
1500, 4-pole
|
180 M ... 315 L
|
18.5 ... 200
|
1470 ... 1490
|
120 ... 1282
|
34.5 ... 340
|
1000, 6-pole
|
180 M ... 315 L
|
15 ... 160
|
975 ... 990
|
147 ... 1543
|
29.5 ... 280
|
750, 8-pole
|
180 M ... 315 L
|
11 ... 132
|
725 ... 740
|
145 ... 1704
|
23.5 ... 240
|
For implementation in the North American market according to EPACT 60 Hz
|
3600, 2-pole
|
180 M ... 315 L
|
30 ... 300
|
3560 ... 3591
|
60 ... 595
|
34 ... 320
|
1800, 4-pole
|
180 M ... 315 L
|
25 ... 300
|
1775 ... 1792
|
100 ... 1193
|
31 ... 335
|
1200, 6-pole
|
180 M ... 315 L
|
20 ... 200
|
1178 ... 1192
|
121 ... 1195
|
25.5 ... 235
|
Cast-iron series 1LA8 50 Hz for mains-fed operation 3)
|
3000, 2-pole
|
315 ... 450
|
250 ... 1000
|
2979 ... 2986
|
801 ... 3200
|
415 ... 1020
|
1500, 4-pole
|
315 ... 450
|
250 ... 1000
|
1488 ... 1492
|
1600 ... 6400
|
430 ... 1060
|
1000, 6-pole
|
315 ... 450
|
200 ... 800
|
988 ... 993
|
1930 ... 7690
|
345 ... 1100
|
750, 8-pole
|
315 ... 450
|
160 ... 630
|
739 ... 744
|
2070 ... 8090
|
295 ... 1160
|
Cast-iron series 1PQ8 50 with standard insulation 500 V 3)
|
3000, 2-pole
|
315 ... 450
|
250 ... 1000
|
2979 ... 2986
|
801 ... 3200
|
415 ... 1020
|
1500, 4-pole
|
315 ... 450
|
250 ... 1000
|
1488 ... 1492
|
1600 ... 6400
|
430 ... 1060
|
1000, 6-pole
|
315 ... 450
|
200 ... 800
|
988 ... 993
|
1930 ... 7690
|
345 ... 1100
|
750, 8-pole
|
315 ... 450
|
160 ... 630
|
739 ... 744
|
2070 ... 8090
|
295 ... 1160
|
Motors for converter-fed operation 1LA8 3) with normal and special insulation or 1PQ8 3) , for special insulation, see Non-standard motorsframe size 315 and above.
1) Motor series 1LA5 is not possible for Zone 2.
2) Motor series 1LA7 is only possible for Zone 2 in frame size 63 M and above.
3) Motor series 1LA8 and 1PQ8 are not possible for Zone 21.
|
|