Обзор
Обзор
Preliminary selection of the motor according to motor type/series, speed or number of poles, frame size, rated output, rated torque, rated speed and rated current
Self-ventilated motors for temperature/time classes F200 and F300
Speed (No. of poles)
|
Frame size
|
Rated output
|
Rated speed
|
Rated torque
|
Rated current at 400 V
|
rpm
|
|
kW
|
rpm
|
Nm
|
A
|
Aluminum series 1LA7 and 1LA5, cast-iron series 1LG6 (motors with external fan)
|
3000, 2-pole
|
80 M ... 315 L
|
0.75 ... 200
|
2830 ... 2985
|
2.5 ... 640
|
2.1 ... 325
|
1500, 4-pole
|
80 M ... 315 L
|
0.55 ... 200
|
1395 ... 1488
|
3.7 ... 1284
|
1.86 ... 345
|
1000, 6-pole
|
80 M ... 315 L
|
0.37 ... 160
|
910 ... 990
|
3.9 ... 1543
|
1.2 ... 285
|
1500/3000, 4-/2-pole
|
80 M ... 160 L
|
The electrical data can be calculated and supplied on receipt of order.
|
1000/1500, 6-/4-pole
|
80 M ... 200 L
|
|
750/1500, 8-/4-pole
|
80 M ... 200 L
|
|
Forced-air cooled motors for temperature/time classes F200 and F300
Speed (No. of poles)
|
Frame size
|
Rated output
|
Rated speed
|
Rated torque
|
Rated current at 400 V
|
rpm
|
|
kW
|
rpm
|
Nm
|
A
|
Aluminum series 1PP7 and 1PP5, cast-iron series 1PP6 (motors without an external fan)
|
3000, 2-pole
|
80 M ... 315 L
|
0.75 ... 200
|
2830 ... 2985
|
2.5 ... 640
|
2.1 ... 325
|
1500, 4-pole
|
80 M ... 315 L
|
0.55 ... 200
|
1395 ... 1488
|
3.7 ... 1284
|
1.86 ... 345
|
1000, 6-pole
|
80 M ... 315 L
|
0.37 ... 160
|
910 ... 990
|
3.9 ... 1543
|
1.2 ... 285
|
1500/3000, 4-/2-pole
|
80 M ... 160 L
|
The electrical data can be calculated and supplied on receipt of order.
|
1000/1500, 6-/4-pole
|
80 M ... 200 L
|
|
750/1500, 8-/4-pole
|
80 M ... 200 L
|
|
Self-ventilated motors for temperature/time class F400
Speed (No. of poles)
|
Frame size
|
Rated output
|
Rated speed
|
Rated torque
|
Rated current at 400 V
|
rpm
|
|
kW
|
rpm
|
Nm
|
A
|
Cast-iron series 1LA6 and 1LG6 (motors with external fan)
|
3000, 2-pole
|
100 L ... 315 L
|
3 ... 190
|
2875 ... 2982
|
10 ... 608
|
6.5 ... 325
|
1500, 4-pole
|
100 L ... 315 L
|
2.2 ... 200
|
1410 ... 1490
|
15 ... 1284
|
5.5 ... 345
|
1000, 6-pole
|
100 L ... 315 L
|
1.5 ... 160
|
925 ... 990
|
15 ... 1546
|
4.5 ... 285
|
1500/3000, 4-/2-pole
|
100 L ... 160 L
|
The electrical data can be calculated and supplied on receipt of order.
|
1000/1500, 6-/4-pole
|
100 L ... 160 L
|
|
750/1500, 8-/4-pole
|
100 L ... 160 L
|
|
Forced-air cooled motors for temperature/time class F400
Speed (No. of poles)
|
Frame size
|
Rated output
|
Rated speed
|
Rated torque
|
Rated current at 400 V
|
rpm
|
|
kW
|
rpm
|
Nm
|
A
|
Cast-iron series 1PP6 (motors without external fan)
|
3000, 2-pole
|
100 L ... 315 L
|
3 ... 190
|
2875 ... 2982
|
10 ... 608
|
6.5 ... 325
|
1500, 4-pole
|
100 L ... 315 L
|
2.2 ... 200
|
1410 ... 1490
|
15 ... 1284
|
5.5 ... 345
|
1000, 6-pole
|
100 L ... 315 L
|
1.5 ... 160
|
925 ... 990
|
15 ... 1546
|
4.5 ... 285
|
1500/3000, 4-/2-pole
|
100 L ... 160 M
|
The electrical data can be calculated and supplied on receipt of order.
|
1000/1500, 6-/4-pole
|
100 L ... 160 L
|
|
750/1500, 8-/4-pole
|
100 L ... 160 L
|
|
|
|