SITRANS FUE1010
|
|
Input
|
|
Flow range
|
0 … 12 m/s (0 … 40 ft/s), bi-directional
|
Flow sensitivity
|
0.0003 m/s (0.001 ft/s)
|
Pipe size
|
6.4 mm … 9,14 m (0.25” … 360”)
|
Optional Inputs,
single channel
|
- Current: 2x 4 … 20 mA
- Voltage: 2x 0 … 10 V DC
- Temperature: 2x 4 wire 1 kΩ RTD
- Totalizer commands (clear/hold)
|
Output
|
|
Type 1 and Type 3 outputs
|
- Current: 2x 4 … 20 mA DC
(1 kΩ at 30 V DC)
- Voltage: 2x 0 … 10 V DC
(5 kΩ minimum)
- Status Alarm: 4x SPDT Relays
- Mercury wetted relays
- Frequency: 2x 0 … 5000 Hz
- RS232
|
Optional Type 1 and Type 3 outputs
|
- Mercury wetted relays
- Expanded I/Os (4 additional 4 ... 20 mA outputs) with form c relays
- Expanded I/Os with Mercury wetted relays
|
Accuracy
|
|
Accuracy
|
± 0.5 % ... 1.0 % of flow,
for velocities greater than 0.3 m/s (1 ft/s)
± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s),
for velocities less than 0.3 m/s (1 ft/s)
|
Batch repeatability
|
± 0.15 % of flow,
for velocities greater than 0.3 m/s (1 ft/s)
± 0.0005 m/s (± 0.0015 ft/s),
for velocities less than 0.3 m/s (1 ft/s)
|
Rated operation conditions
|
|
Degree of protection
|
Dedicated wall mount enclosure: IP65 (NEMA 4X)
Portable enclosures: IP40 (NEMA 1)
|
Liquid Temperature
|
|
|
-40 … +120 °C (-40 … +250 °F)
|
|
-40 … +230 °C (-40 … +450 °F)
|
Transducer temperature
|
|
|
-40 … +120 °C (-40 … +250 °F)
|
|
-62 … +232 °C (-80 … +450 °F)
|
Ambient temperature
|
-18 ... +60 °C (0 ... 140 °F)
|
Design
|
|
Dimensions
|
see SITRANS F US Clamp-on "System info and selection guide"
|
Weight
|
see diagrams
|
Power supply
|
90 … 240 V AC, 50 ... 60 Hz, 30 VA
or
9 … 36 V DC, 12 W
|
Indication and operation
|
|
Data logger memory
|
1 Mbyte of storage
|
Display
|
128 x 240 pixel LCD with backlight
|
Keypad
|
33 keypad buttons with tactile feedback
|
Language options
|
English, spanish, german, italian, french
|
Certificates and approvals
|
|
|
- Flow display computer
Ex II (1) G [EEx ia] IIC
Ex II 3 (1) G EEx nC [ia] IIC T5
- Transducers
Ex II 1 G EEx ia IIC T5
Ex II 2 G EEx m II T5 (for use with flowmeter in safe area)
|
- Dedicated wall mount enclosure
|
FM
CSA
CE
- LVD IEC 61010-1
- EMC EN61000-6-2, -4
|
|
UL
ULc
CE
- LVD IEC 61010-1; CB Test Certificate
- EMC EN61000-6-2, -4
|