SITRANS FUP1010
|
|
Input
|
|
Flow range
|
± 12 m/s (± 40 ft/s), bidirectional
|
Pipe size
|
6.4 mm … 9.14 m (0.25”… 360”)
|
Optional inputs,
single channel
|
- Current: 2x 4 … 20 mA DC
- Voltage: 2x 0 … 10 V DC
- Temperature: 2x 4 wire 1 kΩ RTD
|
Output
|
|
Outputs
|
- Current: 2x 4 … 20 mA DC
(1 kΩ at 30 V DC)
- Voltage: 2x 0 … 10 V DC
(5 kΩ minimum)
- Status Alarm: 4x SPDT Relays
- Frequency: 2x 0 … 5000 Hz
- RS232
|
Accuracy
|
|
Accuracy
|
± 0.5 % … 2 % of flow,
for velocities greater than 0.3 m/s (1 ft/s)
± 0.0015 … 0.006 m/s (± 0.005 … 0.02 ft/s),
for velocities less than 0.3 m/s (1 ft/s)
|
Batch repeatability
|
± 0.15 % of flow,
for velocities greater than 0.3 m/s (1 ft/s)
± 0.0005 m/s (± 0.0015 ft/s),
for velocities less than 0.3 m/s (1 ft/s)
|
Rated operation conditions
|
|
Degree of protection
|
|
- Standard portable enclosure
|
IP40 (NEMA 1)
|
- Weatherproof/impact resistant
|
IP67
|
Liquid temperature
|
|
|
-40 … +120 °C (-40 … +250 °F)
|
|
-40 … +230 °C (-40 … +450 °F)
|
Ambient temperature
|
-18 … +60 °C (0 … +140 °F)
|
Design
|
|
Dimensions
|
see SITRANS F US Clamp-on „System info and selection guide“
|
Weight
|
see diagrams
|
Power supply
|
|
Power
|
Internal NiCd battery
|
Battery operation
|
4 hours
|
Indication and operation
|
|
Data logger memory
|
1 MByte
|
Site storage memory
|
50 sites minimum
|
Display
|
128 x 240 pixel LCD with backlight
|
Keypad
|
33 keypad buttons with tactile feedback
|
Language options
|
English, Spanish, German, Italian, French
|
Certificates and approvals
|
|
Unclassified locations only
|
UL
ULc
CE:
- LVD IEC 61010-1; CB Test Certificate
- EMC EN 61000-6-2, -4
|