Область применения
The “F 33 Minireg” board is a current-controlled thyristor power unit with half-controlled single-phase bridge circuit, which is used for the field supply of DC shunt- wound motors.
Current actual value sensing
The current actual value is measured on the DC side of the power section with a chopper converter. With this measuring method, the “zero diode current” of the thyristor circuit is also sensed.
Current controller
When the F 33 Minireg Version 2 is used for the field supply of DC shunt-wound motors, the current controller has the task of keeping the current through the field winding constant, independently of temperature rise and supply voltage fluctuations, according to a specified setpoint.
The setpoint which, for example, corresponds to the rated field, can be set with potentiometer R120.
Заказные данные
Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
6DM1001-0WB00-2 |
1.351 |
Система управления modulpac c minireg "f33" 2-х фазн. 230/400v |
------ |
|
Тех. данные
Дизайн
Subrack 6DM9005 is intended for mounting a total of seven F 33 Miniregs.
The F 33 Minireg can also be mounted on a vertical surface by means of four spacers, e.g. in a cubicle.
Технические данные
Ter-
minal
|
Function
|
Terminal strip codes
|
Con-
nection value
|
Comments
|
L1
L2 (N)
|
Rated supply
voltage
|
|
2-ph. 230 or
400 V 50/60 Hz
|
±10 %
|
L+
L-
|
Rated DC voltage
|
|
DC 190 V or
DC 35 V
|
|
X1.1
X1.2
X1.3
|
Contact terminals of relay
K2
|
NO contact
CO contact
NC contact
|
Contact
rating
AC 230 V, 2.5 A
|
Changeover contact
|
X1.4
|
Controller enable
|
Rf
|
+24 V
^= enable
|
|
X1.5
|
P24
|
P24
|
|
For controller enable
|
X1.6
X1.7
|
Actual
value
output
|
I
|
0 ... -10 V
|
e.g. for measuring purposes
|
X1.8
|
External supple-
mentary
setpoint
|
I*
|
0 ... ±10 V
|
|
X1.9
|
Reference potential M
(0 V)
|
M
|
0 V
|
|
X1.10
|
External supple-.
mentary set-
point
|
|
|
|
X1.13
|
Reference potential M
(0 V)
|
|
|
|
X1.14
|
Tag
|
G
|
|
|
X3.1
X3.2
X3.3
X3.4
X3.5
X3.6
|
Connector for connecting cable to supple-
mentary board
|
P
N
M
N24
ie*
ie ist
|
|
|
|
Protective con-
ductor terminal
|
|
|
|
Rated supply voltage
(50/60 Hz)V
|
Rated DC voltage
V
|
Rated DC current 1)
A
|
Order No..
|
Fuse
|
2-ph. 230
|
190
|
8
|
6DM1001-
0WB00-2
|
5SD420
|
|
|
|
6DM1001-
0WB00-2
|
5SD420
|
|
|
|
6DM1001-
0WB00-2
|
5SD440
|
2-ph. 400
|
325
|
15
|
6DM1001-
0WB00-2
|
5SD420
|
|
|
22
|
6DM1001-
0WB00-2
|
5SD440
|

Дополнительную информацию вы можете получить загрузив
файл в формате PDF (83383 байт).
Чертеж

Дополнительную информацию вы можете получить загрузив
файл в формате PDF (73770 байт).
Схема подключения